0
Items : 0
Subtotal :  0.00
View CartCheck Out
Chennai
Chennai
Singapore
Mumbai
Switzerland
+91 98848 35702 Mon - Fri 09:00 - 18:30 766/1, TEZ, Sakthi Towers 1, Anna salai, Chennai 600 002.
+65 9324 8815 Mon - Fri 09:00 - 18:30 171, TRAS STREET 07 175 UNION BUILDING, SINGAPORE 079025.
+91 98848 35702 Mon - Fri 09:00 - 18:30 5, Powai Lake Heights, Mumbai 400 072
Mon - Fri 09:00 - 18:30 Equvera - ISV Techno SAGL, Via Ligornetto 6A, 6855 Stabio, Switzerland
Ceritified
ISO 9001:2008
The Best
#1 in India
Number #1
AUTOMATION SOLUTION PROVIDER
Talk to an Expert
0
Items : 0
Subtotal :  0.00
View CartCheck Out
csm_Flash_Point_Analyzer_Model_P-500_822acfd03ecsm_Flash_Point_Analyzer_Model_P-500_822acfd03e

Flash Point Analyzer

Model P-500
P-500-1.00
  • Complies with ASTM
  • Capable of handling high sulfur samples
  • Rapid measuring cycle of 5 minutes
  • Independent sample and flash chamber temperature control
  • Micro-processor controlled
  • External programming
  • Color graphics screen
  • Remote diagnostics over IP
Request Quote


    Email Verification Code (required)



    Description
    Technical Data
    Manuals/Operating Instructions/Guides
    Data Sheets
    Brochures

    To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly. The flash point temperature is defined as the lowest temperature at which application of an ignition source causes the vapor of specimen of the sample to ignite under specified conditions of test.

    Marking

    Class I, Division 1, Group B, C and D.Ex db IIB+H2 T6 GbEx db IIB+H2 T6 Gb

    Ambient Temperature

    T6

    Certification
    • IECEx Certificate of Conformity: EN
    • EU-TYPE EXAMINATION CERTIFICATE: EN
    • Certificate of Compliance: EN

    Technical Data

    Technology measurement / small stainless steel flash chamber, spark ignition
    Method complies with ASTM D56 and ASTM D93
    Measuring cycle measuring cycle time is typically 5 minutes or less
    Analog outputs Flash Point, sample temperature
    Digital outputs Sample FP alarm, analyzer maintenance warning, analyzer fault alarm
    Digital inputs customer alarm, remote standby, stream switch, validation request
    Display 7″ color graphics
    Weight approximately 228 kg (500 lbs)
    Dimensions Approximately 940 x 1803 x 762 mm (37 x 71 x 30 inches)
    MODBUS interface TCP/IP or Serial/RTU MODBUS output available

    Manuals/Operating Instructions/Guides

    Data Sheets

    Brochures