csm_KTE-d_Cable_Thermostat_8888af67fbcsm_KTE-d_Cable_Thermostat_8888af67fb

KTE-d

Cable Thermostat
27-6B11-52.. BZ..
  • High switching current
  • Wide operating temperature range
  • Ready for connection
  • Maintenance-free
Request Quote


    Email Verification Code (required)



    Category:
    Description
    Technical Data
    Declarations
    Data Sheets

    The KTE-d is a highly reliable bimetallic thermostat designed for use in hazardous (potentially explosive) areas. It is integrated into a cable and commonly used to protect devices against frost, regulate temperatures of switch and control cabinets, transmitter protection boxes, and measuring equipment. The KTE-d can also be used to indicate excessively high or low temperatures or as an alarm contact. Its ability to conform to the required minimum temperatures ensures exceptional reliability, making it a valuable tool for a wide range of applications.

    Marking

    Ex II 2G Ex db IIC T6Ex II 2D Ex tb IIIC T80 °C

    Ambient Temperature

    Operating temperaturerange: -60 °C to +180 °CAmbient temperaturerange: -60 °C to +60 °C

    Certification
    • IECEx Certificate of Conformity: EN
    • EU Type Examination Certificate: DE
    • TCRU Certificate: RU

    Technical Data

    Control range 10 °C ON/18 °C OFF (+/-3 ° K) fix (mechanical) (others on request)
    Electrical data Voltage: max. AC 250 V (others on request)
    Current: AC 10 A (Switching current)  
    Connection: Flexible cable EWKF 3 x 1.5 mm²; Ø 8.1 mm or single cores
    Mechanical data Material: black anodised aluminium, seawater proof  
    Installation: M 6 internal thread / Through hole d =5 mm or M 20 connection thread

    Declarations