A large number of variants and versions of control and signal device actuator are available for the ComEx control and indicator units.All control and signal device actuator are made of high-quality thermoplastic and can be used in almost all potentially explosive areas.
ATEX/UKEX:Ex II 2G Ex eb IIC GbEx II 2D Ex tb IIIC Db
IECEx:Ex eb IIC GbEx tb IIIC D
CEC (UL Mark):Ex eb IIC GbEx tb IIIC DbClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass III, Division 2
NEC (UL Mark):Class I, Zone 1, AEx eb IIC GbZone 21, AEx tb IIIC DbClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass III, Division 2
Service temperature (Ts):-55 °C to +70 °C(-67 °F to +158 °F)
| Protection class |
Up to IP67 acc. to EN 60529 and NEMA 4X acc. to UL 50E. |
|---|---|
| Mounting |
– Installation in enclosures with a wall thickness of 1mm to 6 mm (0.04 in to 0.24 in) |
| Service temperature | -55 °C to +70 °C (-67 °F to +158 °F) (related to explosion protection acc. to EN IEC 60079-0) |
| Weight | see data sheet |