Bushings and cable entries pressure and vacuum sealed

non explosion-proof
  • Economical, due to high packing density
  • Space-saving, due to internal thread
  • Fast installation with the small flange versions
  • Corrosion-resistant due to high-quality sleeve material
  • Bushing stems with suitable thermo material to ensure unimpaired signals from thermal sensors
Request Quote


    Email Verification Code (required)



    Category:
    Description
    Technical Data
    Questionnaires/Requirement Sheets
    Data Sheets

    Cable entriesElectrical cable entries are components which facilitate the insertion of electric leads into enclosures while providing a secure seal at the point of entry.Line bushingsThe line bushings allow an electrical connection of apparatus in enclosures or the connection of two enclosures.The standard versions are suitable for the application range of 10-6mbar to 63 bar positive pressure depending on the ambient temperature. Depending on the pressure and the medium to be sealed, the bushing / cable entry can be designed for a temperature range of -70 °C to +150 °C.Versions up to 1000 bar are available to suit the temperature at the point of cable entry or bushing and the type of the medium to be sealed. BARTEC cable entries and line bushings in the IP 68 type of protection not only seal the cable sheath, they also protect the inside strands. BARTEC cable entries and line bushings consist in principle of a sleeve into which electric leads and single conductors are embedded in casting resin. Even the standard version of this component series satisfies most of the sealing requirements of modern process technologies.

    Ambient Temperature

    Operating temperature-70 °C to +150 °C (-94 °F to 302 °F)

    Technical Data

    Dimensions see data sheet
    Pressure Nominal pressure: up to 63 bar (at RT = +25 °C)
    Test pressure: 80 bar at RT
    Installation Stud thread M3 to M30
    Voltage Nominal voltage: up to 1000 V
    Current 100 A, 250 A, 315 A (see data sheet)

    Questionnaires/Requirement Sheets

      Customer requirements – Cable entries/line bushings

    Data Sheets

    Data Sheet – Bushings and cable entries pressure and vacuum sealed