0
Items : 0
Subtotal :  0.00
View CartCheck Out
Chennai
Chennai
Singapore
Mumbai
Switzerland
+91 98848 35702 Mon - Fri 09:00 - 18:30 766/1, TEZ, Sakthi Towers 1, Anna salai, Chennai 600 002.
+65 9324 8815 Mon - Fri 09:00 - 18:30 171, TRAS STREET 07 175 UNION BUILDING, SINGAPORE 079025.
+91 98848 35702 Mon - Fri 09:00 - 18:30 5, Powai Lake Heights, Mumbai 400 072
Mon - Fri 09:00 - 18:30 Equvera - ISV Techno SAGL, Via Ligornetto 6A, 6855 Stabio, Switzerland
Ceritified
ISO 9001:2008
The Best
#1 in India
Number #1
AUTOMATION SOLUTION PROVIDER
Talk to an Expert
0
Items : 0
Subtotal :  0.00
View CartCheck Out
07-96.07-96.

Bushing explosion-proof and pressure-sealed

for Zone 1
07-96..-…./..
  • High pressure stability
  • High temperature resistance
Request Quote


    Email Verification Code (required)



    Category:
    Description
    Technical Data
    Questionnaires/Requirement Sheets
    Manuals/Operating Instructions/Guides
    Declarations
    Data Sheets

    The 07-96..-.. type series II 1G line bushing serves as a gas diffusion-proof isolation element for zone 0 (1G/2G) while simultaneously providing an electric connection for leads:- between flameproof enclosures- between flameproof enclosures and enclosures with another approved type of protection Category II 2 G- flameproof enclosures and protected installations Category II 3 G or-in the safe areaThe core piece of this gas diffusion-proof leadthrough is a metal plate in which the stud-type bushings are insulated with glass. The electrical connection on both sides of the lead-through can be set forth with metal duct bolts, cable wires or hose lines as required. This connecting area is, or can additionally be, cast with a poured resin. The connector studs, connecting wires or the hose line of the line bushing II 1G must be connected in enclosures which conform to a type of protection standardised according to DIN EN 60079-0. The lead-through is compliant with the pertinent DIN EN 60079-0, DIN EN 60079-1 and DIN EN 60079-7 and DIN EN 60079-26 standards.

     

    Marking

    ATEX:Ex II 1/2 G Ex db + eb / db IIC Ga/GbEx II 2 G Ex db IIC GbEx II 2 G Ex eb IIC GbEx II 2 G Ex db eb IIC GbEx II -/2 G Ex db eb IIC GbEx II -/2 G Ex eb IIC GbEx I M 1 Ex db eb I Ma

    IECEx:Ex db + eb / db IIC Ga/GbEx db IIC GbEx eb IIC GbEx db eb IIC GbEx db eb I MaEx-marking depend on selected configuration

    Ambient Temperature

    Temperature at rated operation:-55 °C ≤ Ta ≤ +150 °C(-67 °F ≤ Ta ≤ +302 °F) with potting-55 °C ≤ Ta ≤ +200 °C(-67 °F ≤ Ta ≤ +392 °F) without pottingdepending on the lead used and type of sealing

    Certification

    Technical Data

    Protection class IEC 60529/EN 60529
    Dependence on the design
    Material Sleeve: metal
    Insulator: glass
    Pour: EP resin, PU resin
    Bushing bolt: FeNi alloy steel, Niro
    steel
    Pressure -500 mbar to +400 bar depending on the design
    Installation Diameter flansch: Ø 10 mm to 250 mm
    Thread size: M10 x 1 to M72 x 2
    Voltage ≤ AC 50 V/DC 75 V, 250 V, 690 V, 1 000 V
    Current up to 500 A
    Connection Core wires: 0.25 mm² to 16 mm²
    Threaded bolts: M3 to M30
    (max. quantity of connections: 99)

    Questionnaires/Requirement Sheets

    Customer requirements – Cable entries/line bushings

    Manuals/Operating Instructions/Guides

    Operational Instruction Line Bushing explosion-proof and pressuresealed Type 07-96..-…./….

    Declarations

    EU-Declaration of Conformity 01-9600-7C0002

    Data Sheets

    Data Sheet – Bushing explosion-proof and pressure-sealed