csm_Cold_Filter_Plugging_Point_Process_Analyzer_9c50bada45csm_Cold_Filter_Plugging_Point_Process_Analyzer_9c50bada45

Cold Filter Plugging Point Process Analyzer

CFPP-4
  • The only ASTM compliant CFPP process analyzer
  • Identical test mesh filter as used in the laboratory
  • Stepped and linear cooling
  • Network and fieldbus communication
Request Quote


    Email Verification Code (required)



    Description
    Technical Data
    Application Notes
    Questionnaires/Requirement Sheets
    Data Sheets
    Brochures

    To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly.The cold filter plugging point (CFPP) is the lowest temperature at which diesel and domestic heating fuels will pass through a filter in a given time when cooled under certain conditions. CFPP is supposed to give an estimate for the lowest temperature at which these fuels will flow in fuel systems without problems. This temperature is important especially in cold temperature regions where high CFPP of diesel fuel could result in clogging up vehicles’ fuel systems.

    Marking

    ATEX: II 2G Ex h IIC T4 Gb XIECEx: Ex IIC T4 GbNEC 500: Class I, Division 2, Group B,C and DNEC 505: Class I, Zone 1, AEx db eb ib pxb IICT3 resp. T4CEC Sec. 18: Ex db eb ib pxb IIC T3 resp. T4TR CU: II Gb T4 X

    Ambient Temperature

    T4

    Technical Data

    Technology discontiniously mearement of CFPP with linear cooling bath
    Method compliant with: ASTM D 6371 DIN EN 116 DIN EN 16329 (linear cooling bath) IP 309
    Sample at inlet filtered 50 μm, no suspended water ( 500 ppm), bubble-free
    10 to 40 l/h
    1 to 4 bar (14.5 to 58
    psi)
    max. 40 °C, max. 37 cSt at inlet temperatur
    Sample at outlet atmospheric pressure
    Electrical data max. 8 outputs (4 to 20 mA; 1000 Ω), active isolated on request
    4 to 20 mA; 160 Ω
    DC 24 V; max.
    0.5 A; sum alarm Ready/Come-Read, Power identification
    high: DC 15 to 28 V; low: DC 0 to 4 V
    Communication MODBUS RTU/TCP (RS485, RS422, VDSL/FO (IS)
    MODBUS/TCP via FOC is
    remote software with modem,
    ISDN, Ethernet via VDSL modem FO (FS)
    Ambient conditions operation 5 to 35 °C (41 to 95 °F) storage -20 to 60 °C (-4 to 140 °F)
    operation 5 to 80 % relative
    humidity, non-corrosive; storage 5 to 80 % relative humidity, non-corrosive
    IP 54 (comparable with
    NEMA 13)
    HMI touch display 19″
    remote access on request
    cyber security
    operating system Windows10
    enterprise LTSB
    Bartec Benke control software PACS
    Process connections tube fittings: typically Swagelok 6mm/12mm/18mm; others on request
    sample inlet for 1 sample stream
    and 1 validation stream
    sample outlet
    vent line (if required)
    coolant (if required)
    Weight and dimensions approx. 400 kg
    (W x H x D) approx. 1140 x 2130 x 710 mm
    free space right: 150 mm/left: 100 mm

    Application Notes

      BENKE CFPP-4 Understanding the challenges of the measurement of the Cold Filter Plugging Point

    Questionnaires/Requirement Sheets

      Questionnaire_PL AMS_PAT

    Data Sheets

      BENKE Cold Filter Plugging Point Process Analyzer CFPP-4

    Brochures

      BENKE Cold Filter Plugging Point Process Analyzer CFPP-4
      Cyber Security Solutions for BARTEC BENKE analyzers