CPU with Motion functionality up to 6 Pulse Axis.
CPU with Motion and CNC functionality. Up to 4 Pulse Axis and 64 EtherCAT Axis.
Model | 0.75 KW – 1.5 KW | 2.2 KW |
---|---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 220 (Single Phase) | 220 (Single Phase) |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way | 2-way |
Digital input | 6-way | 6-way |
Analog output | 2-way | 2-way |
Digital output | 1-way | 1-way |
Relay output | 2-way | 2-way |
RS485 communication terminal | 1-way | 1-way |
Power supply | 2-way, 1-way 24V | 2-way, 1-way 24V |
Altitude | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m |
Environment Temperature (°C) | -10 ~ +40 (derated 40 ~ 50) | -10 ~ +40 (derated 40 ~ 50) |
Humidity | <95% RH, no water condensation | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 ~ +60 | -40 ~ +60 |
Material | ABS + PC | ABS + PC |
Size H x W x D (mm) | 187 x 88 x 138 | 207 x 100 x 147 |
Weight | 1.4 | 1.7 |
CE | YES | YES |
Model | 4.0 KW | 5.5 – 7.5 KW |
---|---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 220 (Three Phase) ± 15% | 220 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way | 2-way |
Digital input | 6-way | 6-way |
Analog output | 2-way | 2-way |
Digital output | 1-way | 1-way |
Relay output | 2-way | 2-way |
RS485 communication terminal | 1-way | 1-way |
Power supply | 2-way, 1-way 24V | 2-way, 1-way 24V |
Altitude | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m |
Environment Temperature (°C) | -10 ~ +40 (derated 40 ~ 50) | -10 ~ +40 (derated 40 ~ 50) |
Humidity | <95% RH, no water condensation | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 ~ +60 | -40 ~ +60 |
Material | ABS + PC | Metal |
Size H x W x D (mm) | 247 x 130 x 167 | 348 x 182 x 211 |
Weight | 2.7 | 7 |
CE | YES | YES |
Model | 11 KW | 15 – 18.5 KW |
---|---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 220 (Three Phase) ± 15% | 220 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way | 2-way |
Digital input | 6-way | 6-way |
Analog output | 2-way | 2-way |
Digital output | 1-way | 1-way |
Relay output | 2-way | 2-way |
RS485 communication terminal | 1-way | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 | -40 + 60 |
Material | Metal | Metal |
Size H x W x D (mm) | 373 x 220 x 205 | 435 x 256 x 222 |
Weight (kg) | 11 | 14 |
CE | YES | YES |
Model | 93 KW | 110 – 130 KW |
---|---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 220 (Three Phase) ± 15% | 220 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way | 2-way |
Digital input | 6-way | 6-way |
Analog output | 2-way | 2-way |
Digital output | 1-way | 1-way |
Relay output | 2-way | 2-way |
RS485 communication terminal | 1-way | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m |
Environment Temperature (°C) | -10 ~ +40 (derated for 40 ~ 50) | -10 ~ +40 (derated for 40 ~ 50) |
Humidity | <95% RH, no condensation | <95% RH, no condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 ~ +60 | -40 ~ +60 |
Material | Metal | Metal |
Size H x W x D (mm) | 869 x 502 x 355 | 1570 x 600 x 408 |
Weight (kg) | 89 | 180 |
CE | YES | YES |
Model | 160 – 200 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 220 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, derate 1% capacity every 100 m above 1000 m |
Environment Temperature (°C) | -10 ~ +40 (derated for 40 ~ 50) |
Humidity | <95% RH, no condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 ~ +60 |
Material | Metal |
Size H x W x D (mm) | 1696 x 800 x 408 |
Weight (kg) | 246 |
CE | YES |
Model | 0.75 KW – 2.2 KW | 4.0 KW |
---|---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way | 2-way |
Digital input | 6-way | 6-way |
Analog output | 2-way | 2-way |
Digital output | 1-way | 1-way |
Relay output | 2-way | 2-way |
RS485 communication terminal | 1-way | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 | -40 + 60 |
Material | ABS + PC | ABS + PC |
Size H x W x D (mm) | 187 x 88 x 138 | 207 x 100 x 147 |
Weight | 1.4 | 1.7 |
CE | YES | YES |
Model | 5.5 – 7.5 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | ABS + PC |
Size H x W x D (mm) | 247 x 130 x 167 |
Weight | 2.7 |
CE | YES |
Model | 11 – 15 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 348 x 182 x 211 |
Weight | 7 |
CE | YES |
Model | 18.5 – 22 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 373 x 220 x 205 |
Weight | 11 |
CE | YES |
Model | 30 – 37 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 435 x 256 x 222 |
Weight | 14 |
CE | YES |
Model | 45 – 55 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 543 x 310 x 280 |
Weight | 23 |
CE | YES |
Model | 75 – 90 – 110 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 580 x 358 x 328 |
Weight | 39 |
CE | YES |
Model | 132 – 160 – 185 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 869 x 502 x 355 |
Weight | 89 |
CE | YES |
Model | 200 – 250 – 280 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 1570 x 600 x 408 |
Weight | 180 |
CE | YES |
Model | 315 – 355 – 400 KW |
---|---|
Control mode | V/F Control; Sensorless Vector Control (SVC); Torque Control |
Starting torque | G Type: 0.5Hz / 150 % (SVC); P Type: 0.5Hz / 100% |
Speed adjustment range | 1:100 (SVC) |
Speed holding precision | ± 0.5 % (SVC) |
Overload Capacity | G Type: 150 % rated current for 60s; 180 % rated current for Is P Type: 120 % rated current for 60s; 150 % rated current for Is |
Input voltage (Vac) | 380 (Three Phase) ± 15% |
Input frequency | 50 / 60 Hz, fluctuation range: ±5% |
Output voltage | 0-rated input voltage |
Output frequency | SVC: 0 ~ 320 Hz, V/F: 0 ~ 1000 Hz |
Analog input | 2-way |
Digital input | 6-way |
Analog output | 2-way |
Digital output | 1-way |
Relay output | 2-way |
RS485 communication terminal | 1-way |
Power supply | 2-way, l-way l 0\61-way 24V |
Altitude | Lower than 1000 m, Service is derated capability above 1000 m, derate 1% capacity every 100 m increased in height. |
Environment Temperature (°C) | -10 ~ + 40 (service is derated capability for 40 ~ 50) |
Humidity | <95% RH, no water condensation |
Vibration Resistance | < 5.9 m/s² (0.6g) |
Storage Temperature (°C) | -40 + 60 |
Material | Metal |
Size H x W x D (mm) | 1696 x 800 x 408 |
Weight | 246 |
CE | YES |
CODE | DESCRIPTION |
---|---|
VB-2SR75GB | Inverter Monophase 220 V 0.75 Kw (Costant Torque Load Torque Load) |
VB-2S1R5GB | Inverter Monophase 220 V 1.5 Kw (Costant Torque Load Torque Load) |
VB-2S2R2GB | Inverter Monophase 220 V 2.2 Kw (Costant Torque Load Torque Load) |
VB-2TR75GB | Inverter Triphase 380 V 0.75 Kw (Costant Torque Load Torque Load) |
VB-2T1R5GB | Inverter Triphase 380 V 1.5 Kw (Costant Torque Load Torque Load) |
VB-2T2R2GB | Inverter Triphase 380 V 2.2 Kw (Costant Torque Load Torque Load) |
VB-2T004GB | Inverter Triphase 380 V 4 Kw (Costant Torque Load Torque Load) |
VB-2T5R5GB | Inverter Triphase 380 V 5.5 Kw (Costant Torque Load Torque Load) |
VB-2T7R5GB | Inverter Triphase 380 V 7.5 Kw (Costant Torque Load Torque Load) |
VB-2T011G | Inverter Triphase 380 V 11 Kw (Costant Torque Load Torque Load) |
VB-2T015G | Inverter Triphase 380 V 15 Kw (Costant Torque Load Torque Load) |
VB-2T18R5GB | Inverter Triphase 380 V 18.5 Kw (Costant Torque Load Torque Load) |
VB-2T022PB | Inverter Triphase 380 V 22 Kw (Variable Torque Load) |
VB-2T022GB | Inverter Triphase 380 V 22 Kw (Costant Torque Load Torque Load) |
VB-2T030PB | Inverter Triphase 380 V 30 Kw (Variable Torque Load) |
VB-2T030G | Inverter Triphase 380 V 30 Kw (Costant Torque Load Torque Load) |
VB-2T037P | Inverter Triphase 380 V 37 Kw (Variable Torque Load) |
VB-2T037G | Inverter Triphase 380 V 37 Kw (Costant Torque Load Torque Load) |
VB-2T045P | Inverter Triphase 380 V 45 Kw (Variable Torque Load) |
VB-2T045G | Inverter Triphase 380 V 45 Kw (Costant Torque Load Torque Load) |
VB-2T055P | Inverter Triphase 380 V 55 Kw (Variable Torque Load) |
VB-2T055G | Inverter Triphase 380 V 55 Kw (Costant Torque Load Torque Load) |
VB-2T075P | Inverter Triphase 380 V 75 Kw (Variable Torque Load) |
VB-2T075G | Inverter Triphase 380 V 75 Kw (Costant Torque Load Torque Load) |
VB-2T093P | Inverter Triphase 380 V 93 Kw (Variable Torque Load) |
VB-2T093G | Inverter Triphase 380 V 93 Kw (Costant Torque Load Torque Load) |
VB-2T110P | Inverter Triphase 380 V 110 Kw (Variable Torque Load) |
VB-2T110G | Inverter Triphase 380 V 110 Kw (Costant Torque Load Torque Load) |
VB-2T132P | Inverter Triphase 380 V 132 Kw (Variable Torque Load) |
VB-2T132G | Inverter Triphase 380 V 132 Kw (Costant Torque Load Torque Load) |
VB-2T160G | Inverter Triphase 380 V 160 Kw (Costant Torque Load Torque Load) |
VB-2T185G | Inverter Triphase 380 V 185 Kw (Costant Torque Load Torque Load) |
VB-2T200G | Inverter Triphase 380 V 200 Kw (Costant Torque Load Torque Load) |
CODE | DESCRIPTION |
---|---|
VB-4TR75GB | Inverter Triphase 380 V 0.75 Kw (Costant Torque Load Torque Load) |
VB-4T1R5GB | Inverter Triphase 380 V 1.5 Kw (Costant Torque Load Torque Load) |
VB-4T2R2GB | Inverter Triphase 380 V 2.2 Kw (Costant Torque Load Torque Load) |
VB-4T004GB | Inverter Triphase 380 V 4 Kw (Costant Torque Load Torque Load) |
VB-4T5R5GB | Inverter Triphase 380 V 5.5 Kw (Costant Torque Load Torque Load) |
VB-4T5R5PB | Inverter Triphase 380 V 5.5 Kw (Variable Torque Load Torque Load) |
VB-4T7R5GB | Inverter Triphase 380 V 7.5 Kw (Costant Torque Load Torque Load) |
VB-4T7R5PB | Inverter Triphase 380 V 7.5 Kw (Variable Torque Load Torque Load) |
VB-4T011GB | Inverter Triphase 380 V 11 Kw (Costant Torque Load Torque Load) |
VB-4T015PB | Inverter Triphase 380 V 15 Kw (Variable Torque Load Torque Load) |
VB-4T015GB | Inverter Triphase 380 V 15 Kw (Costant Torque Load Torque Load) |
VB-4T18R5PB | Inverter Triphase 380 V 18.5 Kw (Variable Torque Load Torque Load) |
VB-4T18R5GB | Inverter Triphase 380 V 18.5 Kw (Costant Torque Load Torque Load) |
VB-4T022PB | Inverter Triphase 380 V 22 Kw (Variable Torque Load) |
VB-4T022GB | Inverter Triphase 380 V 22 Kw (Costant Torque Load Torque Load) |
VB-4T030PB | Inverter Triphase 380 V 30 Kw (Variable Torque Load) |
VB-4T030G | Inverter Triphase 380 V 30 Kw (Costant Torque Load Torque Load) |
VB-4T037P | Inverter Triphase 380 V 37 Kw (Variable Torque Load) |
VB-4T037G | Inverter Triphase 380 V 37 Kw (Costant Torque Load Torque Load) |
VB-4T045P | Inverter Triphase 380 V 45 Kw (Variable Torque Load) |
VB-4T045G | Inverter Triphase 380 V 45 Kw (Costant Torque Load Torque Load) |
VB-4T055P | Inverter Triphase 380 V 55 Kw (Variable Torque Load) |
VB-4T055G | Inverter Triphase 380 V 55 Kw (Costant Torque Load Torque Load) |
VB-4T075P | Inverter Triphase 380 V 75 Kw (Variable Torque Load) |
VB-4T075G | Inverter Triphase 380 V 75 Kw (Costant Torque Load Torque Load) |
VB-4T093P | Inverter Triphase 380 V 93 Kw (Variable Torque Load) |
VB-4T093G | Inverter Triphase 380 V 93 Kw (Costant Torque Load Torque Load) |
VB-4T110P | Inverter Triphase 380 V 110 Kw (Variable Torque Load) |
VB-4T110G | Inverter Triphase 380 V 110 Kw (Costant Torque Load Torque Load) |
VB-4T132P | Inverter Triphase 380 V 132 Kw (Variable Torque Load) |
VB-4T132G | Inverter Triphase 380 V 132 Kw (Costant Torque Load Torque Load) |
VB-4T160P | Inverter Triphase 380 V 160 Kw (Variable Torque Load) |
VB-4T160G | Inverter Triphase 380 V 160 Kw (Costant Torque Load Torque Load) |
VB-4T185P | Inverter Triphase 380 V 185 Kw (Costant Torque Load Torque Load) |
VB-4T185G | Inverter Triphase 380 V 185 Kw (Variable Torque Load) |
VB-4T200P | Inverter Triphase 380 V 200 Kw (Costant Torque Load Torque Load) |
VB-4T200G | Inverter Triphase 380 V 200 Kw (Variable Torque Load) |
VB-4T220P | Inverter Triphase 380 V 220 Kw (Costant Torque Load Torque Load) |
VB-4T220G | Inverter Triphase 380 V 220 Kw (Variable Torque Load) |
VB-4T250P | Inverter Triphase 380 V 250 Kw (Costant Torque Load Torque Load) |
VB-4T250G | Inverter Triphase 380 V 250 Kw (Variable Torque Load) |
VB-4T280P | Inverter Triphase 380 V 280 Kw (Costant Torque Load Torque Load) |
VB-4T280G | Inverter Triphase 380 V 280 Kw (Variable Torque Load) |
VB-4T315P | Inverter Triphase 380 V 315 Kw (Costant Torque Load Torque Load) |
VB-4T315G | Inverter Triphase 380 V 315 Kw (Variable Torque Load) |
VB-4T355P | Inverter Triphase 380 V 355 Kw (Costant Torque Load Torque Load) |
VB-4T355G | Inverter Triphase 380 V 355 Kw (Variable Torque Load) |
VB-4T400P | Inverter Triphase 380 V 400 Kw (Costant Torque Load Torque Load) |
VB-4T400G | Inverter Triphase 380 V 400 Kw (Variable Torque Load) |