Talk to an Expert

Modular PLC

HCM300

CPU with Motion functionality up to 6 Pulse Axis.

HCM500

CPU with Motion and CNC functionality. Up to 4 Pulse Axis and 64 EtherCAT Axis.

HCM300 specifications

Model HCM301-16MT4-D HCM302-16MT4-D HCM310-16MT4-D HCM311-16MT4-D HCM312-32MT6-D
Program capacity 256K (Byte) 256K (Byte) 512K (Byte) 512K (Byte) 512K (Byte)
Variable capacity 256K (Byte) 256K (Byte) 256K (Byte)
(Power-failure holding capacity is 32K)
256K (Byte)
(Power-failure holding capacity is 32K)
256K (Byte)
(Power-failure holding capacity is 32K)
EtherNet
Total number of TCP connections Not supported Not supported 16 (ModbusTCP+Socket + EtherNet/IP) 16 (ModbusTCP+Socket + EtherNet/IP) 16 (ModbusTCP+Socket + EtherNet/IP)
ModbusTCP Not supported Not supported Max. number of client (master) connected: 16
Max. number of server (slave) connected: 16
Max. number of client (master) connected: 16
Max. number of server (slave) connected: 16
Max. number of client (master) connected: 16
Max. number of server (slave) connected: 16
Socket Not supported Not supported Max. number of connections: 8, support TCP/UDP Max. number of connections: 8, support TCP/UDP Max. number of connections: 8, support TCP/UDP
EtherNet/IP
CIP implicit
communication
Not supported Not supported Max. number of connections: 8
The maximum amount of data per connection: 200Byte
Cycle time: 5~1000ms
Max. number of connections: 8
The maximum amount of data per connection: 200Byte
Cycle time: 5~1000ms
Max. number of connections: 8
The maximum amount of data per connection: 200Byte
Cycle time: 5~1000ms
CIP explicit
communication
Not supported Not supported Class3 Connections: 8
The number of clients accessed by UCMM (non-connection type) at the same time: 16
Class3 Connections: 8
The number of clients accessed by UCMM (non-connection type) at the same time: 16
Class3 Connections: 8
The number of clients accessed by UCMM (non-connection type) at the same time: 16
EtherCAT
Transmission speed Not supported Not supported Not supported Not supported Not supported
Topology Not supported Not supported Not supported Not supported Not supported
Transmission medium Not supported Not supported Not supported Not supported Not supported
The maximum transmission
distance between nodes
Not supported Not supported Not supported Not supported Not supported
Maximum number of slaves Not supported Not supported Not supported Not supported Not supported
Process Data Not supported Not supported Not supported Not supported Not supported
Communication cycle Not supported Not supported Not supported Not supported Not supported
Supporting protocols Not supported Not supported Not supported Not supported Not supported
RS485: Max numbers of slaves 32 32 32 32 32
USB 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade
CAN communication interface Not supported Not supported Not supported Not supported 1 channel (requires CAN optional card), supports 16 channels of slave stations
SD Card Not supported Not supported Not supported Not supported 1
Number of electronic cams Not supported 16 Not supported 16 16
Electronic cam: number of key points of
a single curve
Not supported 32 Not supported 32 32
Max number of axis groups Not supported 1 axis group (maximum 8-axis interpolation per axis group) Not supported 1 axis group (maximum 8-axis interpolation per axis group) 1 axis group (maximum 8-axis interpolation per axis group)
EtherCAT axis Not supported Not supported Not supported Not supported Not supported
Number of pulse axes 4 axes 200K 4 axes 200K 4 axes 200K 4 axes 200K 6 axes 200K
Number of encoder axes 2 2 2 2 2
Real axis + imaginary axis Total number≤16 Total number≤16 Total number≤16 Total number≤16 Total number≤16
Max. number of expansion
modules
16 16 16 16 16
Maxi. number of optional
cards
Not supported Not supported Not supported Not supported 2
Input points 8 inputs: Support 8-ch external interrupt; 2-ch 100K
high-speed pulse input (AB phase, pulse + direction, single pulse)
8 inputs: Support 8-ch external interrupt; 2-ch 100K
high-speed pulse input (AB phase, pulse + direction, single pulse)
8 inputs: Support 8-ch external interrupt; 2-ch 200K
high-speed pulse input (AB phase, pulse + direction, single pulse)
8 inputs: Support 8-ch external interrupt; 2-ch 200K
high-speed pulse input (AB phase, pulse + direction, single pulse)
16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
Output points 8 outputs NPN: Support 4-ch 100K high-speed
pulse output (pulse + direction)
8 outputs NPN: Support 4-ch 100K high-speed
pulse output (pulse + direction)
8 outputs NPN: Support 4-ch 200K high-speed
pulse output (pulse + direction)
8 outputs NPN: Support 4-ch 200K high-speed
pulse output (pulse + direction)
16 outputs NPN: Support 6-ch
200K high-speed pulse
output (pulse + dir ection)
Serial port RS485 1-ch: Can be used as Modbus master or slave(Maximum support for 32 slave stationswhen acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 32 slave stationswhen acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 32 slave stationswhen acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 32 slave stationswhen acting as the master station), support free protocol 2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
Serial port RS232 1-ch: Can be used as Modbus master or slave(Maximum support for 1 slave station when acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 1 slave station when acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 1 slave station when acting as the master station), support free protocol 1-ch: Can be used as Modbus master or slave(Maximum support for 1 slave station when acting as the master station), support free protocol Optional card required
Input voltage DC24V (±10%) DC24V (±10%) DC24V (±10%) DC24V (±10%) DC24V (±10%)
Allowable momentary power failure time It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms
Rated power 5W 5W 5W 5W 5W
Operating temperature 0 +55°C 0 +55°C 0 +55°C 0 +55°C 0 +55°C
Storage temperature -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation)
Relative humidity 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation)
Certification CE CE CE CE CE

HCM500S Specifications

Model HCM500S-16MT4-D HCM501S-16MT4-D HCM511S-32MT4-D
Program capacity 512K (Byte) 512K (Byte) 512K (Byte)
Variable capacity 256K (Byte)
(Power-failure holding capacity is 32K)
256K (Byte)
(Power-failure holding capacity is 32K)
256K (Byte)
(Power-failure holding capacity is 32K)
EtherNet
Total number of TCP connections Not supported Not supported 12 (ModbusTCP+Socket)
ModbusTCP Not supported Not supported Max. number of client (master) connected: 4
Max. number of server (slave) connected: 4
Socket Not supported Not supported Max. number of connections: 4, support TCP/UDP
EtherNet/IP
CIP implicit
communication
Not supported Not supported Not supported
CIP explicit
communication
Not supported Not supported Not supported
EtherCAT
Transmission speed 100Mbps (100Base -TX) 100Mbps (100Base -TX) 100Mbps (100Base -TX)
Topology Linear Linear Linear
Transmission medium Standard EtherCAT communication cable Standard EtherCAT communication cable Standard EtherCAT communication cable
The maximum transmission
distance between nodes
100 metres 100 metres 100 metres
Maximum number of slaves 4 (Only devices listed in SysCtrl Studio) 8 (Only devices listed in SysCtrl Studio) 8 (Only devices listed in SysCtrl Studio)
Process Data 1380 bytes (the maximum number of frames is 1) 1380 bytes (the maximum number of frames is 1) 1380 bytes (the maximum number of frames is 1)
Communication cycle 500us 500us 500us
Supporting protocols EtherCAT Master station EtherCAT Master station EtherCAT Master station
RS485: Max numbers of slaves 32 32 32
USB 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade
CAN communication interface Not supported Not supported 1 channel (requires CAN optional card), supports 16 channels of slave stations
SD Card Not supported Not supported Not supported
Number of electronic cams 16 16 16
Electronic cam: number of key points of
a single curve
32 32 32
Max number of axis groups 1 axis group (maximum 8-axis interpolation per axis group) 1 axis group (maximum 8-axis interpolation per axis group) 1 axis group (maximum 8-axis interpolation per axis group)
Gcode capacity Not supported Not supported Not supported
EtherCAT axis 4 (Only devices listed in SysCtrl Studio) 8 (Only devices listed in SysCtrl Studio) 8 (Only devices listed in SysCtrl Studio)
Number of pulse axes 4 axes 200K 4 axes 200K 4 axes 200K
Number of encoder axes 2 2 2
Real axis + imaginary axis Total number≤16 Total number≤16 Total number≤16
Max. number of expansion modules 16 16 16
Max. number of optional cards Not supported Not supported 2
Input points 8 inputs 8 inputs 16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
Output points 8 outputs NPN 8 outputs NPN 16 outputs NPN: Support 4-ch
200K high-speed pulse
output (pulse + direction)
Serial port RS485 1-ch 1-ch 2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
Serial port RS232 1-ch 1-ch Optional card required
Input voltage DC24V (±10%) DC24V (±10%) DC24V (±10%)
Allowable momentary power failure time It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms
Rated power 5W 5W 5W
Operating temperature 0 +55°C 0 +55°C 0 +55°C
Storage temperature -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation)
Relative humidity 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation)
Certification CE CE CE

HCM500 Specifications

Model HCM511-32MT4-D HCM512-32MT4-D HCM513-32MT4-D HCM514-32MT4-D
Program capacity 20 MB 20 MB 20 MB 20 MB
Variable capacity 20 MB (Byte)
(Power-failure holding capacity is 128K)
20 MB (Byte)
(Power-failure holding capacity is 128K)
20 MB (Byte)
(Power-failure holding capacity is 128K)
20 MB (Byte)
(Power-failure holding capacity is 128K)
EtherNet
Total number of TCP connections 16 (ModbusTCP+Socket + EtherNet/IP) 16 (ModbusTCP+Socket + EtherNet/IP) 16 (ModbusTCP+Socket + EtherNet/IP) 16 (ModbusTCP+Socket + EtherNet/IP)
ModbusTCP Max. number of client (master) connected:16 Max. number of server (slave) connected:16 Max. number of client (master) connected:16 Max. number of server (slave) connected:16 Max. number of client (master) connected:16 Max. number of server (slave) connected:16 Max. number of client (master) connected:16 Max. number of server (slave) connected:16
Socket Max. number of connections:8, support TCP/UDP Max. number of connections:8, support TCP/UDP Max. number of connections:8, support TCP/UDP Max. number of connections:8, support TCP/UDP
EtherNet/IP
CIP implicit
communication
Max. number of connections:8 The maximum amount of data per connection:200Byte Cycle time:5~1000ms Max. number of connections:8 The maximum amount of data per connection:200Byte Cycle time:5~1000ms Max. number of connections:8 The maximum amount of data per connection:200Byte Cycle time:5~1000ms Max. number of connections:8 The maximum amount of data per connection:200Byte Cycle time:5~1000ms
CIP explicit
communication
Class3 Connections:8 The number of clients accessed by UCMM (non-connection type) at the same time: 16 Class3 Connections:8 The number of clients accessed by UCMM (non-connection type) at the same time: 16 Class3 Connections:8 The number of clients accessed by UCMM (non-connection type) at the same time: 16 Class3 Connections:8 The number of clients accessed by UCMM (non-connection type) at the same time: 16
EtherCAT
Transmission speed 100Mbps (100Base -TX) 100Mbps (100Base -TX) 100Mbps (100Base -TX) 100Mbps (100Base -TX)
Topology Linear Linear Linear Linear
Transmission medium Standard EtherCAT communication cable Standard EtherCAT communication cable Standard EtherCAT communication cable Standard EtherCAT communication cable
The maximum transmission
distance between nodes
100 metres 100 metres 100 metres 100 metres
Maximum number of slaves 16 32 64 128
Process Data 1380 bytes (the maximum number of frames is 1) 1380 bytes (the maximum number of frames is 1) 1380 bytes (the maximum number of frames is 1) 1380 bytes (the maximum number of frames is 1)
Communication cycle 250us 250us 250us 250us
Supporting protocols EtherCAT Master station EtherCAT Master station EtherCAT Master station EtherCAT Master station
RS485: Max numbers of slaves 32 32 32 32
USB 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade 1 channel TypeC: Support program upload and download, software monitoring and debugging, firmware upgrade
CAN communication interface 1 channel (requires CAN optional card), supports 16 channels of slave stations 1 channel (requires CAN optional card), supports 16 channels of slave stations 1 channel (requires CAN optional card), supports 16 channels of slave stations 1 channel (requires CAN optional card), supports 16 channels of slave stations
SD Card 1 1 1 1
Number of electronic cams 64 64 64 64
Electronic cam: number of key points of a single curve 2048 2048 2048 2048
Max number of axis groups 8 axis group (maximum 8-axis interpolation per axis group) 8 axis group (maximum 8-axis interpolation per axis group) 8 axis group (maximum 8-axis interpolation per axis group) 8 axis group (maximum 8-axis interpolation per axis group)
Gcode capacity 16M (support up to 64 G-code files, each up to 256k) 16M (support up to 64 G-code files, each up to 256k) 16M (support up to 64 G-code files, each up to 256k) 16M (support up to 64 G-code files, each up to 256k)
EtherCAT axis 8 16 32 64
Number of pulse axes 4 axes 200K 4 axes 200K 4 axes 200K 4 axes 200K
Number of encoder axes 2 2 2 2
Real axis + imaginary axis Total number≤64 Total number≤64 Total number≤64 Total number≤128
Max. number of expansion modules 16 16 16 16
Maxi. number of optional cards 2 2 2 2
Input points 16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
16 inputs: Support 8 external interrupts;
2-ch 200K high-speed pulse input (AB phase, pulse + direction, single pulse)
Output points 16 outputs NPN: Support 4-ch
200K high-speed pulse
output (pulse + direction)
16 outputs NPN: Support 4-ch
200K high-speed pulse
output (pulse + direction)
16 outputs NPN: Support 4-ch
200K high-speed pulse
output (pulse + direction)
16 outputs NPN: Support 4-ch
200K high-speed pulse
output (pulse + direction)
Serial port RS485 2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
2-ch: Can be used as a Modbus master or slave
(up to 32 slaves when used as a master), and supports free protocols
Serial port RS232 Optional card required Optional card required Optional card required Optional card required
Input voltage DC24V (±10%) DC24V (±10%) DC24V (±10%) DC24V (±10%)
Allowable momentary power failure time It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms It will continue to operate for instantaneous power failures within 5ms
Rated power 5W 5W 5W 5W
Operating temperature 0 +55°C 0 +55°C 0 +55°C 0 +55°C
Storage temperature -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation) -25 +70°C (no condensation)
Relative humidity 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation) 10%~95% (no condensation)
Certificaton CE CE CE CE

Coupler Specifications

Model HCMX-EC01-D HCMXC-MD16-D HCMXP-MD16-D
Power supply 24 Vdc 24 Vdc 24 Vdc
Communication protocol EtherCAT CANopen Profinet
Number of expandable modules 16 16 16
Input specifications Not supported 8 8
Output specifications (NPN) Not supported 8 8
Communication rate 100 Mbps 1 Mbps 100 Mbps
Max. communication distance 100 m 5000 m 100 m
Operation mode Free Run, SM-Synchron, DC-Synchron

Digital Input / Output Specifications

CODES HCMX-ID08-D HCMX-ID16-D HCMX-ID32-D HCMX-OD08-D-PNP HCMX-OD16-D-PNP HCMX-OD32-D-PNP HCMX-MD16-D-PNP HCMX-MD32-D-PNP HCMX-OC08-D
Input points 8 16 32 8 16
Rated input voltage DC24V(±10%) DC24V(±10%) DC24V(±10%) DC24V(±10%) DC24V(±10%)
Input type Source/sink Source/sink Source/sink Source/sink Source/sink
Rated input current 5mA 5mA 5mA 5mA 5mA
ON-current >4mA >4mA >4mA >4mA >4mA
OFF-current <2.5mA <2.5mA <2.5mA <2.5mA <2.5mA
ON-Voltage ≥15V DC ≥15V DC ≥15V DC ≥15V DC ≥15V DC
OFF-Voltage ≤5V DC ≤5V DC ≤5V DC ≤5V DC ≤5V DC
Hardware response time (ON/OFF) 100us/100us 100us/100us 100us/100us 100us/100us 100us/100us
Software filtering Supported Supported Supported Supported Supported
Input resistance 2.7K 2.7K 2.7K 2.7K 2.7K
Isolation method Capacitor isolation Capacitor isolation Capacitor isolation Capacitor isolation Capacitor isolation
Output points 8 16 32 8 16 8
Output type Transistor PNP Transistor PNP Transistor PNP Transistor PNP Transistor PNP Relay
Output mode sink sink sink sink sink
Control circuit voltage DC5V~24V DC5V~24V DC5V~24V DC5V~24V DC5V~24V AC250V / DC30V
Rated load current (resistance) 0.5A/point 4A/module 0.5A/point 4A/module 0.5A/point 4A/module 0.5A/point 2A/module 0.5A/point 2A/module 2A/point 8A/module
Rated load current (inductance) 7.2W/point 24W/module 7.2W/point 24W/module 7.2W/point 24W/module 7.2W/point 12W/module 7.2W/point 12W/module 1A/point 4A/module
Rated load current (lamp) 5W/point 18W/module 5W/point 18W/module 5W/point 18W/module 5W/point 10W/module 5W/point 10W/module 5W/point 18W/module
Leakage current at OFF <10μA <10μA <10μA <10μA <10μA
Hardware response time (ON/OFF) 500us/500μs 500us/500μs 500us/500μs 500us/500μs 500us/500μs
Output frequency Resistive load 100Hz
Inductive load 0.5Hz
Lamp load 10Hz
Resistive load 100Hz
Inductive load 0.5Hz
Lamp load 10Hz
Resistive load 100Hz
Inductive load 0.5Hz
Lamp load 10Hz
Resistive load 100Hz
Inductive load 0.5Hz
Lamp load 10Hz
Resistive load 100Hz
Inductive load 0.5Hz
Lamp load 10Hz
Resistive load 1Hz
Inductive load 0.5Hz
Lamp load 1Hz
Isolation method Capacitor isolation Capacitor isolation Capacitor isolation Capacitor isolation Capacitor isolation
Protective function Short circuit protection, over current protection Short circuit protection, over current protection Short circuit protection, over current protection Short circuit protection, over current protection Short circuit protection, over current protection
Common method Use a common terminal for every 8 points Use a common terminal for every 8 points Use a common terminal for every 8 points Use a common terminal for every 8 points Use a common terminal every 16 points Use a common terminal every 16 points Use a common terminal for every 8 points Use a common terminal for every 16 points Use a common terminal for every 4 points
Status Display When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up When the input/output is in the driven state, the corresponding indicator lights up
Refresh method when an error occurs Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold
Refresh method when the main unit stops Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold Reset or hold

Analog Input / Output Specifications

CODES HCMX-AD04-D
Input type Voltage and current
Number of input channels 4
Resolution 16 bits
Conversion time 60us/ch
Precision(25°C) ±0.1% full scale
Supported modes and conversion values -10V~10V(-32000~32000)
-5V~5V(-32000~32000)
0V~5V(0-32000)
1V~5V(0-32000)
-20mA~20mA(-32000~32000)
0mA~20mA(0-32000)
4mA~20mA(0-32000)
Voltage input impedance 1MΩ
Voltage input limit ±15V
Current input impedance 250Ω
Current input limit Instantaneous ±30mA, average ±24mA
Filter function Supported
Disconnection detection Supported when the mode is 4mA~20mA
Refresh method when an error occurs Reset or hold
Refresh method when the main unit stops Reset or hold
CODES HCMX-DA04-D
Output type Voltage and current
Number of output channels 4
Resolution 16 bits
Conversion time 60us/ch
Precision(25°C) ±0.1% full scale
Supported modes and conversion values -10V~10V(-32000~32000)
0V~10V(0~32000)
0mA~20mA(0~32000)
4mA~20mA(0~32000)
Voltage output load ≧1KΩ
Current output load ≦600Ω
Refresh method when an error occurs Reset or hold
Refresh method when the main unit stops Reset or hold

BD Communication Board Specifications

CODES HCMXB-2RS232-BD HCMXB-2RS485-BD HCMXB-CAN-BD
Specification overview 2-channel RS232 communication option card 2-channel RS485 communication option card Support CANopen protocol (DS301), can be used as master station or slave station
Link layer CAN2.0A
Terminating resistor External 120Ω
Supported baud rate (bps) 9600, 19200, 38400, 57600, 115200 9600, 19200, 38400, 57600, 115200 20K, 50K, 125K, 250K, 500K, 1M
Topology Point to point 32 slaves Daisy chain / Star-type
Transmission medium Comply with CIA standard CAN communication cable
Maximum communication distance 15 meters 500 meters 2500 meters (at 20Kbit/s)
Sync cycle Min 1ms

BD Encoder Board Specifications

CODES HCMXB-AB-BD
Specification overview AB-phase differential encoder
Counting method AB-phase ×1 frequency / ×2 frequency / ×4 frequency
Counting direction Increase counting / Decrease counting

BD Calendar Board Specifications

CODES HCMXB-RTC-BD
Specification overview Perpetual calendar battery
Clock accuracy ±120s/month
Clock format Year-Month-Day-Hour-Minute-Second
Battery specification Standard replaceable battery, service life 3–5 years

CPU Order Codes

CODES DESCRIPTION
HCM301-16MT4-D PLC/PAC (Without Interpolation), 8 digital input/output (NPN), 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM302-16MT4-D PLC/PAC (With Interpolation), 8 digital input/output (NPN), 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM310-16MT4-D PLC/PAC (Without Interpolation), 8 digital input/output (NPN), 1 x Ethernet, 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM311-16MT4-D PLC/PAC (With Interpolation), 8 digital input/output (NPN), 1 x Ethernet, 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM312-32MT6-D PLC/PAC (With Interpolation), 16 digital input/output (NPN), 1 x Ethernet, 2 x RS485, 1 x USB, 6 x Axes 200 KHz, 2 BD boards
HCM500S-16MT4-D PLC/PAC (Without Interpolation), 8 digital input/output (NPN), 1 x EtherCAT (Max. 4 axes, only devices listed in SysCtrl Studio), 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM501S-16MT4-D PLC/PAC (Without Interpolation), 8 digital input/output (NPN), 1 x EtherCAT (Max. 8 axes, only devices listed in SysCtrl Studio), 1 x RS485, 1 x RS232, 1 x USB, 4 x Axes 200 KHz
HCM511S-32MT4-D PLC/PAC (With Interpolation), 16 digital input/output (NPN), 1 x Ethernet, 1 x EtherCAT (Max. 8 axes, only devices listed in SysCtrl Studio), 2 x RS485, 1 x USB, 4 x Axes 200 KHz, 2 BD boards
HCM511-32MT4-D PLC/PAC (With Interpolation), 16 digital input/output (NPN), 1 x Ethernet, 1 x EtherCAT (Max. 8 axes), G-Code, 2 x RS485, 1 x USB, 4 x Axes 200 KHz, 2 BD boards
HCM512-32MT4-D PLC/PAC (With Interpolation), 8 digital input/output (NPN), 1 x Ethernet, 1 x EtherCAT (Max. 16 axes), G-Code, 2 x RS485, 1 x USB, 4 x Axes 200 KHz, 2 BD boards
HCM513-32MT4-D PLC/PAC (With Interpolation), 16 digital input/output (NPN), 1 x Ethernet, 1 x EtherCAT (Max. 32 axes), G-Code, 2 x RS485, 1 x USB, 4 x Axes 200 KHz, 2 BD boards
HCM514-32MT4-D PLC/PAC (With Interpolation), 16 digital input/output (NPN), 1 x Ethernet, 1 x EtherCAT (Max. 64 axes), G-Code, 2 x RS485, 1 x USB, 4 x Axes 200 KHz, 2 BD boards

Coupler Order Codes

CODES DESCRIPTION
HCMX-ID08-D 8 digital inputs, support source or sink
HCMX-ID16-D 16 digital inputs, support source or sink
HCMX-ID32-D 32 digital inputs, support source or sink
HCMX-OD08-D-PNP 8 digital outputs (transistor), PNP
HCMX-OD16-D-PNP 16 digital outputs (transistor), PNP
HCMX-OD32-D-PNP 32 digital outputs (transistor), PNP
HCMX-MD16-D-PNP 16 I/O points: 8 inputs support source or sink wiring, 8 outputs PNP
HCMX-MD32-D-PNP 32 I/O points: 16 inputs support source or sink wiring, 16 outputs
HCMX-OC08-D 8 digital outputs (relay), 250 Vac / 30 Vdc
HCMX-AD04-D 4 16-bit analog inputs; Supported modes: -10V~10V, -5V~5V, 0V~5V, 1V~5V, -20mA~20mA, 0mA~20mA, 4mA~20mA
HCMX-DA04-D 4 16-bit analog outputs; Supported modes: -10V~10V, 0V~10V, 0~20mA, 4mA~20mA

Input/Output Order Codes

CODES DESCRIPTION
HCMX-ID08-D 8 digital inputs, support source or sink
HCMX-ID16-D 16 digital inputs, support source or sink
HCMX-ID32-D 32 digital inputs, support source or sink
HCMX-OD08-D-PNP 8 digital outputs (transistor), PNP
HCMX-OD16-D-PNP 16 digital outputs (transistor), PNP
HCMX-OD32-D-PNP 32 digital outputs (transistor), PNP
HCMX-MD16-D-PNP 16 I/O points : 8 input supports source or sink wiring, 8 output PNP
HCMX-MD32-D-PNP 32 I/O points : 16 input supports source or sink wiring, 16 output
HCMX-OC08-D 8 digital outputs (relay), 250 Vac/ 30 Vdc
HCMX-AD04-D 4 16-bit analog inputs; Supported modes:-10V~10V 、-5V~5V、0V~5V、1V~5V、-20mA~20mA、0mA~20mA、4mA~20mA
HCMX-DA04-D 4 16-bit analog outputs; Supported modes:-10V~10V 、0V~10V、0~20mA、4mA~20mA

BD module Order Codes

CODES DESCRIPTION
HCMXB-2RS232-BD 2-channel RS232 serial port
HCMXB-2RS485-BD 2-channel RS485 serial port, can be used as master or slave station, supports Modbus protocol and free protocol
HCMXB-CAN-BD Supports CANopen protocol, can be used as master or slave station
HCMXB-AB-500-BD AB-phase differential encoder (only HCM500 compatible)
HCMXB-RTC-BD Battery module for perpetual calendar