The self-regulating heating cable PSB is suitable for frost protection and temperature maintenance on pipes and vessels at low process temperatures in industry and hazardous areas.The power output of the PSB varies depending on the ambient temperature. If the ambient temperature increases, the heating output will be reduced.While the polyolefin protective jacket is for aqueous, inorganic chemicals, the fluoropolymer protective jacket is suitable for organic chemicals.
ATEX:II 2G Ex 60079-30-1 IIC T6, T5 GbII 2D Ex 60079-30-1 IIIC T80 °C, T95 °C Db
IECEx:Ex 60079-30-1 IIC T6, T5 GbEx 60079-30-1 IIIC T80 °C, T95 °C Db
CSA:Class I, Div. 2, Groups A, B, C, DClass II, Div. 2, Groups E, F, GClass III
Max. continuous operating temperature, energized +65°CMax. continuous exposure temperature, de-energized +85°C