07-3...-07-3...-

Local control stations,for Zone 2/22

for Zone 2/22
A7-3…-…./….
  • The right size/material enclosure
  • Optimum functionality thanks to the great variety of components
  • Customised planning and implementation
  • Certified to many standards
Description
Technical Data
Manuals/Operating Instructions/Guides
Declarations
Data Sheets

BARTEC produces local control stations for use in areas with flammable gases and dusts. Depending on the application area, the control stations are designed with the type of protection “Increased safety” or “Protection by enclosure”.The explosion-protected local control stations are available in aluminium, polyester or stainless steel. When selecting the version, you can choose between a cabinet with door and an enclosure with screw cover. Control, signalling and display devices and remote I/O systems are installed according to customer specifications. The installation of industrial standard equipment in controls for Zone 22, type of protection t “Protection by enclosure” is possible.The control elements can also be mounted on a mounting rail or in the front wall. Free installation areas can be designated for the subsequent installation of BARTEC control and signalling devices, which are then sealed using blanking plugs. All explosion-protected local control stations are supplied prewired on terminals.Fields of applicationChemical and petrochemical industry, process and plant engineering, pharmaceutical and food industry, OFF SHORE areas.

Marking

Zone 2:Ex II 3 G Ex dc ec nA nC mc op is op pr op sh qia/ib/ic [ic] IIA, IIB, IIC T6, T5, T4 GcEx II 3(2) G Ex dc ec nA nC mc op is op sh qia/ib/ic [ib Gb] IIA, IIB, IIC T6, T5, T4 GcEx II 3(1) G Ex dc ec nA nC mc op is op pr op sh qia/ib/ic [ia Ga] IIA, IIB, IIC T6, T5, T4 Gc

Zone 22:Ex II 3D Ex tc op is op sh [ic] IIIA, IIIB, IIICT80 °C, T100 °C DcEx II 3(2)D Ex tc op is op sh [ib Db] IIIA, IIIB, IIICT80 °C, T100 °C DcEx II 3(1)D Ex tc op is op sh [ia Da] IIIA, IIIB, IIICT80 °C, T100 °C Dc

Ambient Temperature

(special design on request)-20 °C ≤ Ta ≤ +40 °C(-4 °F ≤ Ta ≤ +104 °F)-55 °C ≤ Ta ≤ +80 °C(-67 °F ≤ Ta ≤ 176 °F)(depending on fixtures)

Certification

Technical Data

Protection class EN IEC 60529: IP max. IP 66 (higher degree of protection on request)
Material see data sheet
Voltage up to 1000 V
Current max. 160 A depending on devices fitted