07-96.07-96.

Bushing explosion-proof and pressure-sealed

for Zone 1
07-96..-…./..
  • High pressure stability
  • High temperature resistance
Category:
Description
Technical Data
Questionnaires/Requirement Sheets
Manuals/Operating Instructions/Guides
Declarations
Data Sheets

The 07-96..-.. type series II 1G line bushing serves as a gas diffusion-proof isolation element for zone 0 (1G/2G) while simultaneously providing an electric connection for leads:- between flameproof enclosures- between flameproof enclosures and enclosures with another approved type of protection Category II 2 G- flameproof enclosures and protected installations Category II 3 G or-in the safe areaThe core piece of this gas diffusion-proof leadthrough is a metal plate in which the stud-type bushings are insulated with glass. The electrical connection on both sides of the lead-through can be set forth with metal duct bolts, cable wires or hose lines as required. This connecting area is, or can additionally be, cast with a poured resin. The connector studs, connecting wires or the hose line of the line bushing II 1G must be connected in enclosures which conform to a type of protection standardised according to DIN EN 60079-0. The lead-through is compliant with the pertinent DIN EN 60079-0, DIN EN 60079-1 and DIN EN 60079-7 and DIN EN 60079-26 standards.

 

Marking

ATEX:Ex II 1/2 G Ex db + eb / db IIC Ga/GbEx II 2 G Ex db IIC GbEx II 2 G Ex eb IIC GbEx II 2 G Ex db eb IIC GbEx II -/2 G Ex db eb IIC GbEx II -/2 G Ex eb IIC GbEx I M 1 Ex db eb I Ma

IECEx:Ex db + eb / db IIC Ga/GbEx db IIC GbEx eb IIC GbEx db eb IIC GbEx db eb I MaEx-marking depend on selected configuration

Ambient Temperature

Temperature at rated operation:-55 °C ≤ Ta ≤ +150 °C(-67 °F ≤ Ta ≤ +302 °F) with potting-55 °C ≤ Ta ≤ +200 °C(-67 °F ≤ Ta ≤ +392 °F) without pottingdepending on the lead used and type of sealing

Certification

Technical Data

Protection class IEC 60529/EN 60529
Dependence on the design
Material Sleeve: metal
Insulator: glass
Pour: EP resin, PU resin
Bushing bolt: FeNi alloy steel, Niro
steel
Pressure -500 mbar to +400 bar depending on the design
Installation Diameter flansch: Ø 10 mm to 250 mm
Thread size: M10 x 1 to M72 x 2
Voltage ≤ AC 50 V/DC 75 V, 250 V, 690 V, 1 000 V
Current up to 500 A
Connection Core wires: 0.25 mm² to 16 mm²
Threaded bolts: M3 to M30
(max. quantity of connections: 99)

Questionnaires/Requirement Sheets

Customer requirements – Cable entries/line bushings

Manuals/Operating Instructions/Guides

Operational Instruction Line Bushing explosion-proof and pressuresealed Type 07-96..-…./….

Declarations

EU-Declaration of Conformity 01-9600-7C0002

Data Sheets

Data Sheet – Bushing explosion-proof and pressure-sealed