csm_SILAS_wW_0fb4d58c6fcsm_SILAS_wW_0fb4d58c6f

SILAS Controller

Ex pzc control unit for Zone 2/22
A7-3741-1110/.00.
  • Small design
  • Easy to handle
  • Separate purging gas input and output
Request Quote


    Email Verification Code (required)



    Description
    Technical Data
    Manuals/Operating Instructions/Guides
    Declarations
    Data Sheets

    The SILAS Controller serves to monitor electrical equipment set up in accordance with the “pressurised apparatus with leakage compensation” process.It is a complete safety device, which consists of a type A7-3741-1110/.00. SILAS Controller and a type 17-51P3-1604 pressure control device.An optional digital purging gas valve to supply protective gas is also necessary.

    Marking

    ATEX:Ex II 3G Ex ec nC [pzc] IIC T4 Gc-20 °C to +60 °CEx II 3G Ex ec nC [pzc] IIC T6 Gc-20 °C to +40 °CEx II 3D Ex tc [pzc] IIIB T85 °C Dc

    IECEx:Ex ec nC [pzc] IIC T4 Gc-20 °C to +60 °CEx ec nC [pzc] IIC T6 Gc-20 °C to +40 °CEx tc [pzc] IIIB T85 °C Dc

    Ambient Temperature

    Operating temperature-20 °C to +60 °C @ T4(-4 °F to 140 °F @ T4)-20 °C to +40 °C @ T6(-4 °F to 104 °F @ T6)Storage temperature-20 °C to +60 °C(-4 °F to 140 °F)

    Certification

    Technical Data

    Protection class min. IP 54
    Pressure range 0 to 25 mbar for all pressure switching levels
    Purge time 0 to 60 minutes (adjustable)
    Temperatures

    Operating temperature
    -20 °C to +60 °C @ T4 (-4 °F to 140 °F @ T4)
    -20 °C to +40 °C @
    T6 (-4 °F to 104 °F @ T6)
    Storage temperature
    -20 °C to +60 °C
      (-4 °F to 140
    °F)

    Voltage AC 230 V / 50 to 60 Hz
    AC 115 V / 50 to 60 Hz
    DC 24 V
    Power max. 8 W
    Display single-line LC display
    Operation – 1 power switch
    – 1 BCD switch for selecting parameters
    – 3 buttons for changing parameters
    – 3 LEDs for displaying switching relay status
    – 1 bypass
    Relay 1. Control relay for purge valve
    2. Enable relay Ex p (potential free)
    3. Signal relay for
    status transmission (potentail free)
    Weight 1.2 kg

    Manuals/Operating Instructions/Guides

      Operating Instructions – SILAS Controller

    Declarations

      Declaration of Conformity – Typ A1-3741-7C0001

    Data Sheets

      Data Sheet – SILAS Controller