0
Items : 0
Subtotal :  0.00
View CartCheck Out
Chennai
Chennai
Singapore
Mumbai
Switzerland
+91 98848 35702 Mon - Fri 09:00 - 18:30 766/1, TEZ, Sakthi Towers 1, Anna salai, Chennai 600 002.
+65 9324 8815 Mon - Fri 09:00 - 18:30 171, TRAS STREET 07 175 UNION BUILDING, SINGAPORE 079025.
+91 98848 35702 Mon - Fri 09:00 - 18:30 5, Powai Lake Heights, Mumbai 400 072
Mon - Fri 09:00 - 18:30 Equvera - ISV Techno SAGL, Via Ligornetto 6A, 6855 Stabio, Switzerland
Ceritified
ISO 9001:2008
The Best
#1 in India
Number #1
AUTOMATION SOLUTION PROVIDER
Talk to an Expert
0
Items : 0
Subtotal :  0.00
View CartCheck Out
csm_03_PNA_149522caeecsm_03_PNA_149522caee

PNA cable glands

Ex d single seal cable glands for zone 1/2 – 21/22
PNA..PNAB
  • For unarmoured cables
  • Single compression type for indoor and outdoor use
  • IP 66 or IP66/68
  • Barrier cable glands series PNAB
Category:
Description
Technical Data
Manuals/Operating Instructions/Guides
Declarations
Data Sheets

Flameproof Ex d cable glands for unarmoured cables BARTEC PNA series are designed to be installed in industrial plants, where potential hazardous atmospheres occur.These areas are either classified as zone 1 and 2 or as zone 21 and 22.Suitable for every unarmoured cablesour PNA series has a single compression type for indoor and outdoor use

 

Marking

ATEX:(Ex II 2 G) Ex db IIC Gb(Ex II 2 G) Ex eb IIC Gb(Ex II 2 G) Ex ia IIC Gb(EX II 3 G) Ex nR IIC Gc(Ex II 2 D) Ex tb IIIC Db(EX II 3 D) Ex tc IIIC Dc IP66 or IP68

IECEx:Ex db IIC GbEx eb IIC GbEx ia IIC GbEx nR IIC GcEx tb IIIC DbEx tc IIIC Dc IP66 or IP66/68

Ambient Temperature

-40 °C to +90 °C standard(rubber rings EPDM-60)-60 °C to +180 °C on demand(rubber rings SILICON)

Certification
  • ATEX (Ex d): EN
  • ATEX (Ex nR): EN
  • IECEx: EN
  • CCC: EN
  • ECASEx: EN
  • INMETRO: PT
  • CCOE-PESO: EN
  • IEC (BS.EN.50262/BS.6121-1): EN

Technical Data

Protection class IP 66 or IP 68 (IEC/EN 60529)
Material Marine grade Aluminium alloy
Stainless steel AISI 316L
Nickel plated brass OT-58
Weight see data sheet
Dimensions see data sheet
Accessories
Quantity of cable entries
Voltage
Current
Imapct test

Manuals/Operating Instructions/Guides

ATEX – Instruction for use
IECEx – Instruction for use
Barrier Cable Glands – sealing only instructions
INMETRO – Instruction of use

Declarations

ATEX (Ex d) – Declaration of conformity
IECEx – Declaration of conformity
ATEX (Ex nR) – Declaration of conformity

Data Sheets

Data sheet – PNA, Cable glands unarmoured cables
Data sheet – PNAB Barrier cable glands